SS2188 (HCl)

Electrochemical HCl Sensor (0~20ppm)

SS2188 is an electrochemical hydrogen chloride (HCl) sensor measuring 0–20 ppm, ideal for leakage detection and TLV monitoring in semiconductor and chemical industries.

KEY FEATURES
    • Measurement range: 0–20 ppm (Max overload: 40 ppm)
    • Output signal: 200 ± 50 nA / ppm
    • Response time: T90 < 50 sec
    • Resolution: <0.5 ppm (typical)
    • Repeatability: < ±2% of signal
    • Operating life: >24 months in air
    • Operating temperature: -20℃ to +50℃
    • Low cross-sensitivity (NO, CO, NH₃, SO₂, etc.)
Product Inquiry

SS2188 (HCl)

Electrochemical Hydrogen Chloride Sensor (0–20ppm)

DESCRIPTION

The SS2188 is an electrochemical sensor designed to detect hydrogen chloride (HCl) in the range of 0–20 ppm. It is ideal for leak detection and TLV (Threshold Limit Value) monitoring in semiconductor and chemical industry environments.


KEY FEATURES

- Measuring Range: 0–20 ppm (Max overload: 40 ppm)
- Output Signal: 200 ± 50 nA / ppm
- Response Time: T90 < 50 sec
- Resolution: <0.5 ppm (typical)
- Repeatability: Within ±2% of signal
- Operating Life: ≥24 months in air
- Operating Temperature: -20℃ to +50℃
- Low Cross Sensitivity: Minimal interference from NO, CO, NH₃, SO₂


Product Specifications
Performance Characteristics
Output Signal200±50 nA / ppm
Typical Baseline Range (pure air, @ 20°C)± 0.5 ppm HCl equivalent
Baseline Shift (-20°C ~ +50°C)< ±2 ppm typical
Response Time (T90)< 60 seconds
FilterNone
Measurement Range0 ~ 20 ppm
Maximum Overload40 ppm
LinearityLinear
Repeatability< ±2% of signal
Recommended Load Resistor10 Ω
Resolution (Electronics Dependent)< 0.5 ppm typical
Bias Voltage0 mV
Environmental
Temperature Range Continuous-20°C to +50°C
Pressure Range800 to 1200 mbar
Operating Humidity Range15% to 90% RH
Lifetime
Long Term Output Drift<5% per annum
Recommended Storage Temp0°C to 20°C
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch
Intrinsic Safety Data
Maximum at 40 ppm10 μA
Maximum o/c Voltage< 1.0 V
Maximum s/c Current< 0.1 A
Sensor Specifications
Accessories
Download
PDF
Datasheet
Download