PRODUCTS

Technology for Future

Product

SS2158 (SO₂)

Electrochemical SO₂ Sensor (0~20ppm)

SS2158 is an electrochemical sulfur dioxide (SO₂) sensor with a measurement range of 0–20 ppm, optimized for both portable and fixed detectors with built-in H₂S interference filter.

KEY FEATURES
    • Measurement range: 0–20 ppm (Max overload: 100 ppm)
    • Output signal: 250 ± 100 nA / ppm
    • Response time: T90 < 30 sec
    • Resolution: <0.1 ppm (typical)
    • Built-in H₂S filter (1000 ppm·hours capacity)
    • Long-term output drift: <15% per annum
    • Expected operating life: >24 months in air
    • Operating temperature: -20℃ to +50℃
Product Inquiry

SS2158 (SO₂)

Electrochemical Sulfur Dioxide Sensor (0–20ppm)

DESCRIPTION

The SS2158 is an electrochemical sensor designed to accurately detect sulfur dioxide (SO₂) within a 0–20 ppm range. It features an output of 250 ± 100 nA/ppm, a fast response time of less than 30 seconds (T90), and a high resolution below 0.1 ppm. A built-in H₂S interference filter (capacity: 1000 ppm·hours) ensures stable performance in various industrial environments. With a lifespan of over 24 months in air and an operating temperature range of -20℃ to +50℃, the SS2158 is ideal for applications such as industrial safety, air quality monitoring, and vehicle emission control.


KEY FEATURES

- Measuring Range: 0–20 ppm (Max overload: 100 ppm)
- Output Signal: 250 ± 100 nA / ppm
- Response Time: T90 < 30 sec
- Resolution: <0.1 ppm (typical)
- H₂S Filter: Built-in 1000 ppm·hours H₂S interference filter
- Long-Term Output Drift: <15% per year
- Operating Life: ≥24 months in air
- Operating Temperature: -20℃ to +50℃


Product Specifications
Performance Characteristics
Output Signal250±100 nA / ppm
Typical Baseline Range (pure air, @ 20°C)≤ ±0.5 ppm SO₂ equivalent
Response Time (T90)< 30 seconds
Filter1000 ppm·hours capacity for removing H₂S
Measurement Range0–20 ppm
Maximum Overload100 ppm
LinearityLinear
Repeatability< ±10% of signal
Recommended Load Resistor10 ohms
Resolution (Electronics Dependent)< 0.1 ppm typical
Bias Voltage0 mV
Environmental
Temperature Range Continuous-20°C to +50°C
Pressure Range800 to 1200 mbar
Operating Humidity Range15% to 90% RH
Lifetime
Long Term Output Drift< 15% per annum
Recommended Storage Temp0°C to 20°C
Expected Operating Life> 24 months in air
Standard Warranty12 months from date of dispatch
Intrinsic Safety Data
Maximum at 100 ppm30 μA
Maximum o/c Voltage< 1.0 V
Maximum s/c Current< 0.1 A
Sensor Specifications
Accessories
Download
PDF
Data Sheets
View in More Languages