PRODUCTS

Technology for Future

Product

SS21P8 (PH₃)

Electrochemical PH₃ Sensor (0~5ppm)

SS21P8 is an electrochemical phosphine (PH₃) gas sensor that detects concentrations from 0 to 5 ppm, ideal for industrial safety monitoring in semiconductor production and other applications.

KEY FEATURES
    • Measurement range: 0–5 ppm (Max overload: 10 ppm)
    • Output signal: 1,000 ± 300 nA / ppm
    • Response time: T90 < 20 sec
    • Resolution: <0.1 ppm (typical)
    • Repeatability: <±5% of signal
    • Operating life: >24 months in air
    • Operating temperature: -20℃ to +50℃
    • Low cross-sensitivity (0% to CO, H₂, NH₃, SO₂, etc.)
Product Inquiry

SS21P8 (PH₃)

Electrochemical PH₃ Sensor (0~5ppm)

DESCRIPTION

SS21P8 is an electrochemical sensor capable of accurately detecting phosphine (PH₃) gas in the 0–5 ppm range. It provides a strong output of 1,000 ± 300 nA/ppm, fast response time (T90 < 20 sec), and high resolution below 0.1 ppm. With excellent repeatability (≤ ±5%) and low cross-sensitivity to gases such as CO, H₂, NH₃, and SO₂, it ensures reliable performance in complex environments. Operating between -20℃ and +50℃, the sensor has a typical lifespan of more than 24 months. Ideal for semiconductor processes and fixed or portable monitoring devices.


KEY FEATURES

- Measurement Range: 0–5 ppm (Max overload: 10 ppm)
- Output Signal: 1,000 ± 300 nA / ppm
- Response Time: T90 < 20 sec
- Resolution: <0.1 ppm (typical)
- Repeatability: ≤ ±5% of signal
- Operating Temperature: -20℃ to +50℃
- Operating Life: ≥24 months in air
- Low Cross-sensitivity: CO, H₂, NH₃, SO₂


Product Specifications
Performance Characteristics
Output Signal1000±300 nA / ppm
Typical Baseline Range (pure air, @ 20℃)±0.1 ppm PH₃ equivalent
Response Time (T90)< 40 seconds
FilterNone
Measurement Range0–5 ppm
Maximum Overload10 ppm
LinearityLinear
Repeatability< ±5% of signal
Recommended Load Resistor10 ohms
Resolution (Electronics Dependent)< 0.1 ppm typical
Bias Voltage0 mV
Environmental
Temperature Range Continuous-20℃ to +50℃
Pressure Range800 to 1200 mbar
Operating Humidity Range15% to 90% RH
Lifetime
Long Term Output Drift< 5% per annum
Recommended Storage Temp0℃ to 20℃
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch
Intrinsic Safety Data
Maximum at 10 ppm20 μA
Maximum o/c Voltage< 1.0 V
Maximum s/c Current< 0.1 A
Sensor Specifications
Accessories
Download
PDF
Datasheet
Download