PRODUCTS

Technology for Future

Product

SS21F8-LE (HCHO)

Electrochemical HCHO Sensor (0~10ppm)

SS21F8_LE is a formaldehyde sensor with low ethanol cross-sensitivity, ideal for accurate indoor air quality monitoring and portable instruments.

KEY FEATURES
    • Measurement range: 0–10 ppm (Max overload: 20 ppm)
    • Output signal: 60 ± 20 nA / ppm
    • Response time: T90 < 30 sec
    • Resolution: ≤0.01 ppm (typical)
    • Expected operating life: ≥24 months in air
    • Operating temperature: -10℃ to +40℃
    • Low cross-sensitivity (≤3% ethanol, 0% NH₃, CO, acetaldehyde, etc.)
Product Inquiry

SS21F8-LE (HCHO)

Electrochemical Formaldehyde Sensor (0–10ppm)

DESCRIPTION

The SS21F8-LE is an electrochemical sensor designed for precise measurement of formaldehyde (HCHO) within the range of 0–10 ppm. With ethanol cross-sensitivity suppressed to below 3%, it offers enhanced accuracy compared to conventional HCHO sensors. It also exhibits negligible cross-interference to ammonia, CO, and acetaldehyde. Featuring a signal output of 60 ± 20 nA/ppm and a high resolution of ≤0.01 ppm, the SS21F8-LE is optimized for high-sensitivity detection. It has a typical operating life of over 24 months in air and performs reliably in a temperature range of -10℃ to +40℃. This sensor is ideal for air purifiers, indoor air quality monitoring systems (IAQ), and portable detectors.


KEY FEATURES

- Measuring Range: 0–10 ppm (Max overload: 20 ppm)
- Output Signal: 60 ± 20 nA / ppm
- Response Time: T90 < 30 sec
- Resolution: ≤0.01 ppm (typical)
- Service Life: ≥24 months (in air)
- Operating Temperature: -10℃ ~ +40℃
- Ethanol Cross-sensitivity: ≤3%
- Other Gas Interference: NH₃, CO, acetaldehyde: 0%


Product Specifications
Performance Characteristics
Output Signal60±20 nA / ppm
Typical Baseline Range (pure air, @ 20℃)≤ ±0.03 ppm
Response Time (T90)< 30 seconds
FilterNone
Measurement Range0-10 ppm
Maximum Overload20 ppm
LinearityLinear
Repeatability≤ ±3%
Recommended Load Resistor10 ohms
Resolution (Electronics Dependent)≤ 0.01 ppm typical
Bias Voltage0 mV
Environmental
Temperature Range Continuous-10℃ to +40℃
Pressure Range800 to 1200 mbar
Operating Humidity Range15% to 90% RH
Lifetime
Long Term Output Drift< 10% per annum
Recommended Storage Temp0℃ to 20℃
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch
Intrinsic Safety Data
Maximum at 20 ppm0.3 mA
Maximum o/c Voltage< 1.0 V
Maximum s/c Current< 0.1 A
Sensor Specifications
Accessories
Download
PDF
Datasheet
Download