PRODUCTS

Technology for Future

Product

SS21F8 (HCHO)

Electrochemical HCHO Sensor (0~10ppm)

SS21F8 is an electrochemical formaldehyde sensor capable of measuring concentrations from 0 to 10 ppm. It is ideal for portable instruments and indoor air quality monitoring applications.

KEY FEATURES
    • Measurement range: 0–10 ppm (Max overload: 20 ppm)
    • Output signal: 200 ± 50 nA / ppm
    • Response time: T90 < 30 sec
    • Resolution: ≤0.01 ppm (typical, electronics dependent)
    • Operating life: >24 months
    • Operating temperature: -10℃ to +40℃
    • Low cross-sensitivity (0% NH₃, 2% CO, 14% acetaldehyde)
Product Inquiry

SS21F8 (HCHO)

Electrochemical Formaldehyde Sensor (0–10ppm)

DESCRIPTION

The SS21F8 is a high-sensitivity electrochemical sensor designed to measure formaldehyde (HCHO) in the 0–10 ppm range. It provides a fast T90 response time of under 30 seconds and a high resolution of 0.01 ppm. With low cross-sensitivity to major gases such as ammonia, carbon monoxide, and acetaldehyde, this sensor is ideal for accurate indoor air quality monitoring. Suitable for portable devices, air purifiers, and IAQ systems, it offers over 24 months of expected lifespan with excellent stability.


KEY FEATURES

- Measuring Range: 0–10 ppm (Max overload: 20 ppm)
- Output Signal: 200 ± 50 nA / ppm
- Response Time: T90 < 30 sec
- Resolution: ≤0.01 ppm (typical, dependent on circuit)
- Operating Life: ≥24 months (in air)
- Operating Temperature: -10℃ ~ +40℃
- Cross-sensitivity: NH₃ 0%, CO 2%, Acetaldehyde 14%


Product Specifications
Performance Characteristics
Output Signal200±50 nA / ppm
Typical Baseline Range (pure air, @ 20℃)≤ ±0.03 ppm
Response Time (T90)< 30 seconds
FilterNone
Measurement Range0-10 ppm
Maximum Overload20 ppm
LinearityLinear
Repeatability≤ ±3%
Recommended Load Resistor10 ohms
Resolution (Electronics Dependent)≤ 0.01 ppm typical
Bias Voltage0 mV
Environmental
Temperature Range Continuous-10℃ to +40℃
Pressure Range800 to 1200 mbar
Operating Humidity Range15% to 90% RH
Lifetime
Long Term Output Drift< 10% per annum
Recommended Storage Temp0℃ to 20℃
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch
Intrinsic Safety Data
Maximum at 20 ppm0.3 mA
Maximum o/c Voltage< 1.0 V
Maximum s/c Current< 0.1 A
Sensor Specifications
Accessories
Download
PDF
Datasheet
Download