PRODUCTS

Technology for Future

Product

SS2168 (Cl₂)

Electrochemical Cl₂ Sensor (0~20ppm)

SS2168 is an electrochemical chlorine gas sensor that detects concentrations from 0 to 20 ppm. It is suitable for use in portable and fixed instruments for industrial safety and ambient air monitoring.

KEY FEATURES
    • Measurement range: 0–20 ppm (Max overload: 50 ppm)
    • Output signal: 700 ± 250 nA / ppm
    • Response time: T90 < 30 sec
    • Resolution: <0.1 ppm (typical, electronics dependent)
    • Operating life: >24 months in air
    • Operating temperature: -20℃ to +50℃
    • Low cross-sensitivity (CO, H₂, H₂S, SO₂, NO)
Product Inquiry

SS2168 (Cl₂)

Electrochemical Chlorine Sensor (0–20ppm)

DESCRIPTION

The SS2168 is an electrochemical sensor designed to accurately measure chlorine (Cl₂) concentrations in the 0–20 ppm range. It offers an output signal of 700 ± 250 nA/ppm, a fast T90 response time of less than 30 seconds, and high sensitivity with a resolution below 0.1 ppm. With minimal cross-sensitivity to gases such as CO, H₂, H₂S, SO₂, and NO, it is ideal for industrial safety applications and air quality monitoring. It operates reliably in a wide temperature range of -20℃ to +50℃ and provides a long service life of over 24 months in ambient air. Easily integrated into portable detectors and fixed gas monitoring systems.


KEY FEATURES

- Measuring Range: 0–20 ppm (Max overload: 50 ppm)
- Output Signal: 700 ± 250 nA / ppm
- Response Time: T90 < 30 sec
- Resolution: <0.1 ppm (typical, circuit dependent)
- Operating Life: ≥24 months (in air)
- Operating Temperature: -20℃ ~ +50℃
- Low Cross-sensitivity: CO, H₂, H₂S, SO₂, NO


Product Specifications
Performance Characteristics
Output Signal-700±250 nA / ppm
Typical Baseline Range (pure air, @ 20℃)±0.5 ppm Cl₂ equivalent
Response Time (T90)< 30 seconds
FilterNone
Measurement Range0-20 ppm
Maximum Overload50 ppm
LinearityLinear
Repeatability2%
Recommended Load Resistor10 ohms
Resolution (Electronics Dependent)< 0.1 ppm typical
Bias Voltage0 mV
Environmental
Temperature Range Continuous-20℃ to +50℃
Pressure Range800 to 1200 mbar
Operating Humidity Range15% to 90% RH
Lifetime
Long Term Output Drift< 10% per annum
Recommended Storage Temp0℃ to 20℃
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch
Intrinsic Safety Data
Maximum at 50 ppm0.1 mA
Maximum o/c Voltage< 1.0 V
Maximum s/c Current< 0.1 A
Sensor Specifications
Accessories
Download
PDF
Datasheet
Download