PRODUCTS

Technology for Future

Product

SS2148 (NO₂)

Electrochemical NO₂ Sensor (0~20ppm)

SS2148 is an electrochemical nitrogen dioxide sensor that measures concentrations from 0 to 20 ppm. It is ideal for use in garage ventilation, diesel vehicle monitoring, and portable ambient air safety systems.

KEY FEATURES
    • Measurement range: 0–20 ppm (Max overload: 40 ppm)
    • Output signal: 220 ± 50 nA / ppm
    • Response time: T90 < 30 sec
    • Resolution: <0.1 ppm (typical)
    • Expected operating life: >24 months in air
    • Operating temperature: -20℃ to +50℃
    • Minimal cross-sensitivity (CO, H₂, H₂S, SO₂, etc.)
Product Inquiry

SS2148 (NO₂)

Electrochemical NO₂ Sensor (0–20ppm)

DESCRIPTION

The SS2148 is an electrochemical sensor designed for accurate detection of nitrogen dioxide (NO₂) in the range of 0–20 ppm. It features a linear output of 220 ± 50 nA/ppm, a fast T90 response time under 30 seconds, and high sensitivity with a resolution below 0.1 ppm. With excellent long-term stability and low cross-sensitivity to interfering gases such as CO, H₂, H₂S, NO, and SO₂, this sensor is ideal for use in vehicle maintenance shops, parking ventilation control, air quality monitoring, and industrial safety systems.


KEY FEATURES

- Measuring Range: 0–20 ppm (Max overload: 40 ppm)
- Output Signal: 220 ± 50 nA / ppm
- Response Time: T90 < 30 sec
- Resolution: <0.1 ppm (typical)
- Operating Life: ≥24 months (in air)
- Operating Temperature: -20℃ ~ +50℃
- Low Cross-sensitivity: CO, H₂, H₂S, NO, SO₂


Product Specifications
Performance Characteristics
Output Signal-200±50 nA / ppm
Typical Baseline Range (pure air, @ 20℃)±0.5 ppm NO₂ equivalent
Response Time (T90)< 30 seconds
FilterNone
Measurement Range0-20 ppm
Maximum Overload40 ppm
LinearityLinear
Repeatability< ±5%
Recommended Load Resistor10 ohms
Resolution (Electronics Dependent)< 0.1 ppm typical
Bias Voltage0 mV
Environmental
Temperature Range Continuous-20℃ to +50℃
Pressure Range800 to 1200 mbar
Operating Humidity Range15% to 90% RH
Lifetime
Long Term Output Drift< 10% per annum
Recommended Storage Temp0℃ to 20℃
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch
Intrinsic Safety Data
Maximum at 200 ppm40 mA
Maximum o/c Voltage< 1.0 V
Maximum s/c Current< 0.1 A
Sensor Specifications
Accessories
Download
PDF
Datasheet
Download