PRODUCTS

Technology for Future

Product

SS2178 (H₂)

Electrochemical H₂ Sensor (0~1,000ppm)

SS2178 is an electrochemical hydrogen gas sensor measuring 0–1,000 ppm, ideal for industrial safety and portable gas detection applications.

KEY FEATURES
    • Measurement range: 0–1,000 ppm (Max overload: 2,000 ppm)
    • Output signal: 30 ± 10 nA / ppm
    • Response time: T90 < 30 sec
    • Resolution: <2 ppm (typical, electronics dependent)
    • Operating life: >24 months
    • Long-term drift: <5% per year
    • Low cross-sensitivity (CO, SO₂, H₂S, NO, NO₂)
Product Inquiry

SS2178 (H₂)

Electrochemical H₂ Sensor (0~1,000ppm)

DESCRIPTION

The SS2178 is an electrochemical hydrogen (H₂) sensor capable of accurately measuring concentrations from 0 to 1,000 ppm. It features a linear output of 30 ± 10 nA/ppm, a fast T90 response time of under 30 seconds, and high sensitivity with a resolution below 2 ppm. The sensor offers low cross-sensitivity to gases such as CO, SO₂, H₂S, and NO, and maintains stable performance with a drift of less than 5% per year. Ideal for use in petrochemical plants, hydrogen storage facilities, refineries, and both fixed and portable gas detectors.


KEY FEATURES

- Measuring Range: 0~1,000 ppm (Max overload: 2,000 ppm)
- Output Signal: 30 ± 10 nA / ppm
- Response Time: T90 < 30 sec
- Resolution: <2 ppm (typical, depending on electronics)
- Operating Life: ≥24 months
- Long-term Output Drift: <5% per year
- Low Cross-sensitivity: CO, SO₂, H₂S, NO


Product Specifications
Performance Characteristics
Output Signal30±10 nA / ppm
Typical Baseline Range (pure air, @ 20℃)≤ ±3 ppm H₂ equivalent
Response Time (T90)< 30 seconds
FilterFilter to reduce CO interference
Measurement Range0–1,000 ppm
Maximum Overload2,000 ppm
LinearityLinear
Repeatability2% of signal
Recommended Load Resistor10 ohms
Resolution (Electronics Dependent)< 2 ppm typical
Bias Voltage0 mV
Environmental
Temperature Range Continuous-20℃ to +50℃
Pressure Range800 to 1200 mbar
Operating Humidity Range15% to 90% RH
Lifetime
Long Term Output Drift< 5% per annum
Recommended Storage Temp0℃ to 20℃
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch
Intrinsic Safety Data
Maximum at 2,000 ppm50 mA
Maximum o/c Voltage< 1.0 V
Maximum s/c Current< 0.1 A
Sensor Specifications
Accessories
Download
PDF
Datasheet
Download