PRODUCTS

Technology for Future

Product

SS2198-HT (H₂S)

Electrochemical H₂S Sensor (0~100ppm)

SS2198_HT is an electrochemical hydrogen sulfide sensor designed for high-temperature and low-humidity environments.
With a wide operating temperature range up to 70℃, it is ideal for fixed detectors used in petrochemical plants and wastewater systems.

KEY FEATURES
    • Measurement range: 0–100 ppm (Max overload: 500 ppm)
    • Optimized for high temperature (up to +70℃)
    • Output signal: 450 ± 80 nA / ppm
    • Resolution: <0.1 ppm (typical)
    • Response time: T90 < 30 sec
    • No response to CO or H₂
    • Low interference from SO₂, NO, NO₂
    • Operating life >24 months
Product Inquiry

SS2198-HT (H₂S)

Electrochemical H₂S Sensor (0~100ppm)

DESCRIPTION

The SS2198_HT is an electrochemical hydrogen sulfide (H₂S) sensor designed for stable performance even in high-temperature and low-humidity environments. It accurately measures H₂S concentrations from 0 to 100 ppm, with an output signal of 450 ± 80 nA/ppm and a fast response time under 30 seconds (T90). The sensor does not react to CO or hydrogen, and offers excellent selectivity with minimal cross-sensitivity to SO₂, NO, and NO₂. With a maximum operating temperature of +70℃ and a service life exceeding 24 months, the SS2198_HT is ideal for fixed installations in petrochemical plants, wastewater treatment, mining, and pipe interiors.


KEY FEATURES

- Measuring Range: 0–100 ppm (Max: 500 ppm)
- High Temperature Operation: Up to +70℃
- Output Signal: 450 ± 80 nA / ppm
- Resolution: <0.1 ppm (typical)
- Response Time: T90 < 30 sec
- No response to CO or H₂
- Low cross-sensitivity to SO₂, NO, NO₂
- Service Life: ≥24 months


Product Specifications
Performance Characteristics
Output Signal450±80 nA / ppm
Typical Baseline Range (pure air, @ 20℃)±2 ppm H₂S equivalent
Response Time (T90)< 30 seconds
FilterNone
Measurement Range0–100 ppm
Maximum Overload500 ppm
LinearityLinear
Repeatability< ±2 ppm H₂S equivalent
Recommended Load Resistor10 ohms
Resolution (Electronics Dependent)< 0.1 ppm typical
Bias Voltage0 mV
Environmental
Temperature Range Continuous-20℃ to +70℃
Pressure Range800 to 1200 mbar
Operating Humidity Range15% to 90% RH
Lifetime
Long Term Output Drift< 5% per annum
Recommended Storage Temp0℃ to 20℃
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch
Intrinsic Safety Data
Maximum at 1,000 ppm40 mA
Maximum o/c Voltage< 1.0 V
Maximum s/c Current< 0.1 A
Sensor Specifications
Accessories
Download
PDF
Datasheet
Download