PRODUCTS

Technology for Future

Product

SS2118 (O₂)

Galvanic cell(lead-oxygen battery) O₂ Sensor (0~25%)

SS2118 is a galvanic-type oxygen sensor designed for accurate measurement of oxygen concentrations from 0 to 25% by volume. Offers linear output, fast T90 response under 15 seconds, and excellent stability. Compact and ideal for portable devices, industrial safety, and combustion analysis. Operates reliably over wide temperature and humidity ranges, with typical lifespan exceeding 24 months in air.

KEY FEATURES
    • Galvanic cell (lead-oxygen battery)
    • Measurement range: 0–25% Vol. O₂ (Max overload: 30%)
    • Output signal: 90 ± 20 μA
    • Fast response time (T90 < 15 sec)
    • Long-term output drift ≤5% per year
    • Operating life ≥24 months in air
    • Temperature range: -20℃ to +50℃
    • Compact design, easy integration
Product Inquiry

SS2118 (O₂)

Galvanic Cell (Lead-Oxygen Battery) O₂ Sensor (0–25%)

DESCRIPTION

SS2118 is a galvanic-type oxygen sensor designed for accurate measurement of oxygen concentrations from 0 to 25% by volume. It provides a linear analog output, fast T90 response time of under 15 seconds, and excellent stability. Its compact form factor makes it ideal for use in portable instruments, industrial safety equipment, and combustion analyzers. The sensor operates reliably over a wide range of temperatures and humidity, with a typical operating life of more than 24 months in ambient air.


KEY FEATURES

- Galvanic Cell (Lead-Oxygen Battery)
- Measurement Range: 0–25% Vol. O₂ (Maximum overload: 30%)
- Output Signal: 90 ± 20 μA
- Fast Response Time: T90 < 15 seconds
- Long-Term Output Drift: ≤5% per year
- Operating Life: ≥24 months in air
- Temperature Range: -20℃ to +50℃
- Compact Design: Easy to integrate into various devices


Product Specifications
Performance Characteristics
Sensor TypeGalvanic cell (lead-oxygen battery)
Measurement Range0–25% Oxygen
Maximum Overload30% Oxygen
Output Signal90~120 µA in air
Response Time (T90)<15 sec for 90% response
Zero current (offset)<0.6% O₂
LinearityLinear
Recommended Load Resistor100 ohm
Bias VoltageNot required
Environmental
Temperature Range Continuous-20°C to +50°C
Pressure Range800 to 1200 mbar
Operating Humidity Range5% to 95% RH
Lifetime
Long Term Output Drift≤5% per annum
Recommended Storage Temp0°C to 20°C
Expected Operating Life24 months in air
Standard Warranty24 months from date of dispatch
Intrinsic Safety Data
Maximum Current in Normal Operation (pure O₂)0.01 A
Maximum no load Voltage (10 to 100% O₂)0.9 V
Maximum short Circuit Current (10 to 100% O₂)0.5 A
Sensor Specifications
Accessories
Download
PDF
Datasheet
Download