PRODUCTS

Technology for Future

Product

SS1118 (O₂)

Galvanic Cell(lead-oxygen battery) O₂ Sensor (0~100%)

SS1118 is a galvanic-type oxygen sensor designed to measure oxygen concentrations from 0 to 100% by volume. Delivers stable, linear output signal with rapid response time and excellent accuracy, ideal for portable instruments, safety monitoring, combustion analysis, and medical applications.
Built-in temperature compensation minimizes drift across varying environments. Typical lifespan exceeds 24 months in air with minimal cross-interference, ensuring reliable performance under wide ambient conditions.

KEY FEATURES
    • Galvanic cell (lead-oxygen battery)
    • Measurement range: 0–100% Vol. O₂
    • Fast response time (T90 < 15 sec)
    • Accuracy: ±1% Full Scale
    • Long operating life (≥24 months in air)
    • Excellent linearity and low cross-interference
Product Inquiry

SS1118 (O₂)

Galvanic Cell (Lead-Oxygen Battery) O₂ Sensor (0–100%)

DESCRIPTION

SS1118 is a galvanic-type oxygen sensor designed to measure oxygen concentrations from 0 to 100% by volume. It offers fast response time, excellent linearity, and high accuracy, making it suitable for portable devices, safety monitoring, combustion analysis, and medical applications. An internal temperature compensation circuit minimizes output drift due to environmental changes. The sensor has a typical lifespan of over 24 months in ambient air.


KEY FEATURES

- Optimized design for portable instruments
- Industrial safety (atmospheric monitoring)
- Combustion efficiency analysis
- Gas mixing process monitoring
- Food storage condition detection
- Medical applications
- Versatile usage in various industries


Product Specifications
Performance Characteristics
Sensor TypeGalvanic cell (lead-oxygen battery)
Measurement Range0–100% Oxygen
Output Signal6±1.5 mV in air @ 25°C 60% RH
Accuracy< ±1.0% Full scale
@ constant temperature and pressure
Response Time (T90)< 15 sec for 90% response
Output LinearityLinear
Zero Offset VoltageLess than 0.5 mV in 100% N₂@ 25°C 40% RH
Cross Interference

Less than 0.1% O₂ response to
0~100% CO₂

0~1% NOx, CO, H₂, H₂S

Environmental
Temperature Range Continuous-10°C to +50°C
Pressure Range700 to 1300 mbar
Operating Humidity Range5% to 95% RH (Non-condensing)
Lifetime
StabilityLess than 1% drift over 8 hours and more
@ constant temperature and pressure
Recommended Storage Temp0°C to 20°C
Expected Operating Life> 24 months in air
Standard Warranty18 months from date of dispatch
Sensor Specifications
Accessories
Download
PDF
Datasheet
Download